Architectural shingles
Metal roofing
Tile roofing
GAF
Owens Corning
Flat & low-slopeFree roof inspection with deck photos before we talk money - GAF and Owens Corning certified installation
IKO Underlayment & Deck Repair: The Boulder City Owner’s Guide
We install IKO-compatible underlayment and handle deck repair across Boulder City, and the installed price usually lands between $1.10 and $2.40 per square foot of underlayment, plus $3 to $9 per square foot when deck sheathing has to be replaced. Small jobs often come in around $650 to $1,600 total; a full tear-off and re-deck with premium IKO underlayment on a typical Boulder City ranch home runs $3,800 to $7,500. Underlayment and deck repair are planned work, not emergency calls, so we schedule them rather than promise them same-day.

Owners usually find this part already gone. They notice a brown water ring spreading on a ceiling in the hallway, or a shingle course near the eave pushing up in a wave after a windy spring. Sometimes a roofer doing an unrelated repair pulls a strip of shingle, looks at the felt underneath, and calls the owner over. In Boulder City the discovery often follows the July-to-September monsoon push, when wind-driven rain finds every gap in aged felt at once. That’s the moment the questions start, and this page answers them for IKO roofs specifically.
Which IKO Models This Applies To
“Underlayment” and “deck” aren’t model-specific in the way a shingle is. IKO underlayment comes in product families – a standard organic felt (IKO Felt 15 and Felt 30, sold in #15 and #30 weights), a synthetic line (IKO Stormtite and its breathable cousins), and specialty self-adhered membranes for ice-dam areas and low-slope transitions. The companion piece is the roof deck itself: OSB or plywood sheathing underneath. So when we match this to your roof, we’re matching three things: the underlayment product, the deck panel thickness and span, and the IKO shingle line above.
Identify what you have before anyone quotes. Pull the manufacturer label off the bundle wrap if you kept it, or read the stamp on the back of a shingle tab. Common IKO asphalt lines on Boulder City homes are Cambridge, Dynasty, and Armourglass. Note the panel grade on the deck: most Boulder City roofs use 7/16-inch OSB, 15/32-inch OSB, or, on older homes, 1x plank sheathing. That panel number changes the price and the repair method.
OEM versus aftermarket is a real decision, and the honest answer for IKO is that the brand of underlayment matters less than the spec. IKO Stormtite and comparable synthetics from GAF, Owens Corning, and CertainTeed all hit similar performance numbers when installed to the same standard. Where it pays to stay IKO is under an IKO shingle system with a full-system warranty, and where the label has to match. We’ll tell you which way we’d go on your roof and why, and we’ll put it in writing. Shepherd & Sons Roofing Boulder City is an independent service provider working with IKO products – not affiliated with, sponsored by, or endorsed by IKO.
Styles & brands we work with
- Architectural shingles
- Metal roofing
- Tile roofing
- GAF
- Owens Corning
- Flat & low-slope
Signs Your IKO Underlayment & Deck Repair Is Failing
- Water staining on ceiling or attic-side sheathing. Felt that has dried out and cracked no longer sheds wind-driven rain, so moisture reaches the deck and soaks through. In Boulder City, the felt dries fast in summer and that drying is exactly what cracks it.
- Wrinkled or wavy shingle courses near the eaves and ridges. Failing underlayment no longer lays flat, and the shingle above telegraphs the wrinkle. Left alone, the wrinkle becomes a wind catch point.
- Soft spots on the roof surface. Walk with care. A soft spot usually means deck sheathing has lost its structure – either rot from water intrusion or a failed panel under a nail line. A soft deck cannot hold fasteners.
- Visible tears or gaps at valleys and penetrations. These are the places underlayment fails first, and they’re the same places wind and water find. A tear at a valley is a direct pathway into the attic.
- Granules and felt debris in the gutter, plus sagging gutter runs. Crumbling felt or sheathing flakes end up in the gutter trough. Sagging gutters pull away from the fascia and let water back up under the first course of shingles.
Note the pattern: two of these five failures start at the deck, not the underlayment. A roofer who quotes only “we’ll replace the felt” without inspecting the panel is quoting half a job.
Replacement Cost & What’s Included
Here’s the range we see in Boulder City on planned underlayment and deck repair work. Every quote is a written line-item estimate – you see the underlayment product by name, the deck panel count, the labor, and the disposal. No change orders for anything we could have counted.
| Line Item | Price Range | Notes |
|---|---|---|
| Synthetic underlayment (installed) | $1.10 – $1.80 / sq ft | IKO Stormtite or spec-equivalent, single layer |
| Organic felt #30 (installed) | $0.85 – $1.30 / sq ft | Budget option on low-slope or shed roofs |
| Self-adhered ice/water membrane at valleys, eaves | $2.20 – $3.60 / sq ft (touched area) | Applied only where the roof detail calls for it |
| Deck sheathing replacement (OSB or plywood) | $3.00 – $5.50 / sq ft | Per-panel pricing available on request |
| Deck sheathing replacement (1x plank to sheathing conversion) | $5.50 – $9.00 / sq ft | Older Boulder City homes; includes new nailing surface |
| Shingle re-and-re (lift, underlayment, re-set) | $2.50 – $4.50 / sq ft | Only where the existing shingle can be salvaged |
The range moves with panel count, roof pitch, and whether the shingles above can be re-set or have to be torn off. Re and re is cheaper per square foot but it’s only possible on shingles that aren’t brittle. In Boulder City, asphalt shingles hit 15 to 20 years of age and then don’t lift cleanly, so most jobs here run as a tear-off.
Every job carries the 90-Day Done Right Promise in writing – if something we did isn’t right, one call brings Bill back and we make it right. No trip charge inside our own county. Free second opinion on any written estimate, including one from another company. Ask before you sign anything.
See the difference
Before
After
Before
After
Before
AfterDIY or Call Us?
What you can safely do yourself: get up on a ladder (with a spotter), look at the shingle field for waves, clear the gutters, photograph the label on the shingle bundle wrap, and count deck panels from the attic side. That’s inspection, and it helps everyone – us and you.
What goes wrong for a DIYer on this exact job: underlayment isn’t a weekend-topping job the way a patch is. Getting it right means the panel nailing schedule follows the shingle manufacturer’s spec, and the underlayment laps run in the correct direction for your slope. Siding, gutters, and ridge vents have to come off around the perimeter of a re-deck, and they don’t survive a rough reinstall. If deck sheathing is soft, walking it with tools in hand is a fall hazard. That’s the point where we tell people plainly: this is roof work, not a Saturday project. If anything you found worries you, call (844) 761-8186. We’ll look and tell you straight.
FAQs
Organic felt (#15 or #30) lasts 10 to 20 years under shingles before it dries and cracks; synthetic underlayment like IKO Stormtite lasts 25 to 35 years installed, and is rated to be left exposed for months during construction. In Boulder City’s summer heat and UV, organic felt takes a beating – the 20-year end of the range is realistic, the 10-year end happens on low-slope or poorly ventilated roofs.
Yes, in limited cases. If the failure is isolated to a valley, a chimney flashing transition, or a single slope – and the surrounding felt still feels pliable when you press it – we can repair locally. If the felt is cracked across more than one slope, or the deck has soft spots, local repair just moves the problem and we’ll say so.
Localized repair on a few squares runs a single day; a full tear-off, deck replacement, new underlayment, and re-roof runs 3 to 6 working days on a typical Boulder City home, depending on panel count and weather. We schedule the work and tell you the callback window before we start – we don’t promise same-day on planned work because nobody re-roofs a house in a day.
We order from suppliers who stock the IKO line. We don’t carry underlayment on a truck, and we don’t claim stock on hand – the material is ordered to your job spec. When you sign off on the estimate, the product name is on it, and the supplier’s delivery slip matches that name. If IKO Stormtite isn’t available in the timing you need, we’ll show you the spec-equivalent from GAF, Owens Corning, or CertainTeed and you choose. Nothing gets substituted without your yes.
Get a Free Estimate on Your IKO Underlayment & Deck Repair
If your IKO roof has water stains, soft spots, wrinkled courses, or a valley you don’t trust, call us. We’ll come out, look at the deck, show you what we see, and put a written line-item estimate in your hands. No trip charge inside our own county, free second opinion on any written estimate, and a 90-Day Done Right Promise on every roofing job we do. Same address since 1996, name on the truck, name on the license, live person answering the phone 24/7. Call (844) 761-8186 today.
Written by the team at Shepherd & Sons Roofing Boulder City, serving Boulder City and nearby areas.